Endoscopic Powder: A Game-Changer in Haemostasis for Minimally Invasive Surgery
The ability to achieve reliable haemostasis is vital in every surgical setting. It not only limits blood loss during surgery but also lowers risks of transfusion and complications after the procedure. In minimally invasive surgeries like laparoscopy or endoscopy, controlling bleeding is especially challenging due to limited space, visibility, and anatomical intricacy.
As more procedures move toward minimally invasive methods, there’s a greater demand for flexible, effective bleeding control solutions when traditional methods aren’t enough.
Challenges of Haemostasis in Minimally Invasive Surgery
Minimally invasive surgery provides advantages including faster healing and minimal scarring, but also presents new obstacles for bleeding control. However, these benefits come with the challenge of difficult bleeding management. Reduced access, poor visualisation, and no sense of touch make handling bleeding in MIS more difficult.
Conventional techniques like suturing, tying off vessels, or cauterization can be difficult to use during MIS. That’s where topical haemostatic agents, especially endoscopic powder, come into play as vital adjuncts to improve visibility, control oozing, and speed up procedures.
Spotlight on Surgi-ORC®-Based Endoscopic Powder
Surgi-ORC® endoscopic powder is a standout, plant-derived, absorbable haemostat with robust clinical backing. ORC was first introduced in 1943 in sheet form and has since evolved to meet the demands of modern MIS through powder formulations.
Why Surgi-ORC®-Based Endoscopic Powder Stands Out
• Effective Haemostasis: ORC facilitates platelet adhesion and aggregation to accelerate clotting
• Shape Plasticity: The granular structure of powdered haemostats and their shape plasticity allows them to conform easily to large and deep surface wounds
• Plant-Based Safety: Free from animal or human components, it reduces risks of immune reactions and disease transmission
• Antibacterial Environment: The oxidation process lowers pH, creating an acidic microenvironment that offers bactericidal benefits
• Biocompatible and Absorbable: Completely resorbed by the body with no cytotoxic effects, even near nerves or vessels
These characteristics make Surgi-ORC® endoscopic powder an ideal choice for managing mild to moderate bleeding—especially capillary, venous, or small arterial oozing in confined spaces.
Optimizing Application with Delivery Devices in MIS
How the powder is delivered greatly influences its effectiveness in surgery. In MIS, bellows pump-based applicators are widely used to deliver endoscopic powder with accuracy and control.
Operation of Endoscopic Powder Applicators
These applicators—resembling syringe-like devices—are equipped with short or long applicator tips designed to deliver the powder through laparoscopic ports or trocars. The bellows mechanism lets surgeons deposit powder accurately without blocking the field of view.
Key Considerations for Optimal Use
• Device Orientation: The angle of application (vertical/horizontal) affects how the powder spreads—often more than compression speed
• Powder Properties: The grain size and flowability, plus moisture sensitivity, impact delivery
• Operator Technique: Delivery efficiency varies based on how quickly and forcefully the bellows are compressed [5]
Real-World Applications of Endoscopic Powder
In surgical settings where access is limited or structures are delicate, endoscopic powder proves invaluable. Because of its conformability, surgeons can treat both broad raw surfaces and deep crevices with ease.
Common Uses Include:
• Laparoscopic liver resections
• Thoracic surgery procedures
• Gynaecology MIS surgeries
• Endoscopic procedures like ESD
• Urological surgeries
By enhancing visibility and enabling faster bleeding control, endoscopic haemostats can shorten operative time, reduce the need for blood products, and contribute to better surgical outcomes [6].
ORC Powder: Efficacy and Safety in Studies
Research on SURGICEL® Powder in 103 surgical patients found:
• Hemostasis was achieved in 87.4% of cases at 5 minutes, and 92.2% at 10 minutes
• Excellent results across open and minimally invasive surgeries
• No complications such as rebleeding, thromboembolism, or side effects reported
• Surgeons found it easy to use, highly effective, and praised the precise delivery with little extra intervention needed
These findings confirm that SURGICEL® Powder is safe, efficient, and versatile, particularly for managing mild-to-moderate bleeding where traditional methods may fall short.
Summary
The future of MIS depends on effective, next-generation haemostatic agents. ORC-based endoscopic powders offer surgeons rapid, flexible, and reliable bleeding control options.
No matter the complexity—be it confined spaces, delicate organs, or irregular wounds—ORC endoscopic powder ensures safe, effective bleeding control for today’s surgical demands.
References
1. Zhang Y, Song D, Huang H, Liang Z, Liu H, Huang Y, Zhong C, Ye G. Minimally invasive hemostatic materials: tackling a dilemma of fluidity and adhesion by photopolymerization in situ. Scientific Reports. 2017 Nov 10;7(1):15250.
2. De la Torre RA, Endoscopic Powder Bachman SL, Wheeler AA, Bartow KN, Scott JS. Hemostasis and hemostatic agents in minimally invasive surgery. Surgery. 2007 Oct 1;142(4):S39-45.
3. Al-Attar N, de Jonge E, Kocharian R, Ilie B, Barnett E, Berrevoet F. Safety and hemostatic effectiveness of SURGICEL® powder in mild and moderate intraoperative bleeding. Clinical and Applied Thrombosis/Hemostasis. 2023 Jul;29:10760296231190376.
4. Xiao X, Wu Z. A narrative review of different hemostatic materials in emergency treatment of trauma. Emerg Med Int. 2022;2022: 6023261
5. Stark M, Wang AY, Corrigan B, Woldu HG, Azizighannad S, Cipolla G, Kocharian R, De Leon H. Comparative analyses of the hemostatic efficacy and surgical device performance of powdered oxidized regenerated cellulose and starch-based powder formulations. Research and Practice in Thrombosis and Haemostasis. 2025 Jan 1;9(1):102668.
6. Bustamante-Balén M, Plumé G. Role of hemostatic powders in the endoscopic management of gastrointestinal bleeding. World Journal of Gastrointestinal Pathophysiology. 2014 Aug 15;5(3):284.
Comments on “The Benefits of Knowing Endoscopic Powder”